emeraudoale4-1
emeraudoale4-2
emeraudoale4-3
emeraudoale4-4
emeraudoale4-1
emeraudoale4-2
emeraudoale4-3
emeraudoale4-4

Ultimate Energy Efficient KOBELCO's Flagship.
By developing state-of-the-art air-ends and optimized package design, we achieved best in class specific power consumption as well as utmost durability.Here, new standard of oil-free compressors starts.

Motor output : 132 - 400kW
Discharge air flow : 18.8 - 66.8 m 3/min
Features

Features

Class-leading specific power consumption

New ALE's performance is evaluated by specific power consumption as per JIS B 8341: 2008 (ISO1217 Edition3 equivalent).KOBELCO places an importance on not only shaft power but also compressor's total input power including energy loss in the compressor because electricity consumption for customers is not shaft power and rated motor power but compressor's total input power.

Unique design to ensure "Oil-free"

KOBELCO's proven dual vent holes design prevents oil entry in compressor chambers during unload running.

Big touch color monitor

Class 0 certified

KOBELCO has received Class 0 certification (ISO8573-1 [-:-:0]) for〈Emeraude ALE〉series from international test institute called TÜV which certifies the highest level of purity for quality classifications of compressed air.

Class 0 certified

Long life cycle

Long Overhaul cycle has been achieved thanks to long life cycle bearings.

Long life cycle

Outstanding quietness

Various noise control techniques has drastically reduced sound level.Making the working environment more comfortable.

Comparison of noise level

Specification

Inverter / Water cooled model

Model Max.Discharge Pressure Free Air Delivery Main motor Discharge Connection Dimensions Noise Level Voltage Weight
50 / 60Hz W×D×H
MPa m3/min cfm kW mm dB(A) kg
ALE132WVⅣ 0.75 24.9 879 132 JIS10k 65A FF 2,705×1,545×1,845 66 380 - 440 3,700
0.86 22.0 777
1.04 19.7 696
ALE160WVⅣ 0.75 29.4 1,038 160 3,800
0.86 26.9 950
1.04 24.9 879
ALE250WVⅣ 0.75 45.4 1,603 250 JIS10k 80A FF 3,150×1,600×2,180 5,350
0.86 41.7 1,473
1.04 38.5 1,360

Inverter / Air cooled model

Model Max.Discharge Pressure Free Air Delivery Main motor Discharge Connection Dimensions Noise Level Voltage Weight
50 / 60Hz W×D×H
MPa m3/min cfm kW mm dB(A) kg
ALE132AVⅣ 0.75 24.1 851 132 JIS10k 65A FF 3,730×1,700×1,995 71 380 - 440 4,300
0.86 21.3 752
ALE160AVⅣ 0.75 28.4 1,003 160 73 4,300
0.86 25.9 915
ALE250AVⅣ 0.75 44.4 1,568 250 JIS10k 80A FF 4,300×1,900×2,180 76 5,600
0.86 40.8 1,441

Motor specifications: IPM motor, 4-pole totally enclosed fan-cooled, Insulation class F, Rated for continuous use Drive system: Step-up gear.

Fixed speed / Water cooled model

Model Max.Discharge Pressure Free Air Delivery Main motor Discharge Connection Dimensions Noise Level Weight
50Hz 60Hz W×D×H Voltage Star-Delta Reactor*
MPa m3/min cfm m3/min cfm kW mm dB(A) kg
ALE132WⅣ 0.75 24.8 876 24.7 872 132 JIS10k 65A FF 2,705×1,545×1,845
《 3,095×1,545×1,845 》
66 380-440 4,100 4,050
0.86 21.6 763 21.8 770 3k,3.3k - 4,100
1.04 20.0 706 19.5 689 6k,6.6k - 4,150
ALE145WⅣ 0.75 26.6 939 26.6 939 145 380-440 4,200 4,150
0.86 24.8 876 24.7 872 3k,3.3k - 4,150
1.04 21.6 763 21.7 766 6k,6.6k - 4,150
ALE160WⅣ 0.75 29.2 1,031 29.1 1,028 160 380-440 4,200 4,150
0.86 26.5 936 26.6 939 3k,3.3k - 4,150
1.04 24.8 876 24.6 869 6k,6.6k - 4,400
ALE200WⅣ 0.75 37.4 1,321 37.4 1,321 200 JIS10k 80A FF 3,150×1,600×2,180
《 3,350×1,600×2,180 》
66 380-440 5,950 5,950
0.86 33.7 1,190 33.5 1,183 3k,3.3k - 5,800
1.04 30.3 1,070 30.2 1,067 6k,6.6k - 5,800
ALE250WⅣ 0.75 45.0 1,589 45.0 1,589 250 380-440 5,950 5,950
0.86 41.4 1,462 41.3 1,458 3k,3.3k - 5,800
1.04 38.1 1,345 38.1 1,345 6k,6.6k - 5,800
ALE275WⅣ 0.75 48.6 1,716 48.6 1,716 275 380-440 6,000 6,000
0.86 44.9 1,586 45.0 1,589 3k,3.3k - 6,200
1.04 41.3 1,458 41.3 1,458 6k,6.6k - 6,400
ALE315WⅣ 0.75 54.6 1,928 54.7 1,932 315 JIS10k 100A FF 《 3,850×2,000×2,400 》 70 380-440 - -
0.86 51.5 1,819 51.2 1,808 3k,3.3k - 9,000
1.04 48.0 1,695 48.0 1,695 6k,6.6k - 9,000
ALE355WⅣ 0.75 63.1 2,228 63.0 2,225 355 380-440 - -
0.86 58.7 2,073 58.9 2,080 3k,3.3k - 9,000
1.04 54.5 1,925 54.6 1,928 6k,6.6k - 9,100
ALE400WⅣ 0.75 66.8 2,359 66.6 2,352 400 75 380-440 - -
0.86 63.0 2,225 62.9 2,221 3k,3.3k - 9,100
1.04 58.7 2,073 58.8 2,077 70 6k,6.6k - 9,150

Motor specifications: Induction motor, 2-pole totally enclosed fan-cooled, Insulation class F, Rated for continuous use Drive system: Step-up gear.
《 》 are for 3k/3.3k,6k/6.6k specification.
* Reactor starter panel is separated.Power sources for main and auxiliary motors are separately needed.
Consult us regarding the size and weight of separate starter panel.

Fixed speed / Air cooled model

Model Max.Discharge Pressure Free Air Delivery Main motor Discharge Connection Dimensions Noise Level Weight
50Hz 60Hz W×D×H Voltage Star-Delta Reactor*
MPa m3/min cfm m3/min cfm kW mm dB(A) kg
ALE132AⅣ 0.75 24.0 848 23.8 840 132 JIS10k 65A FF 3,730×1,700×1,995
《 4,120×1,700×1,995 》
71 380-440 4,700 4,700
0.86 20.9 738 21.0 742 3k,3.3k - 4,600
1.04 19.3 682 18.8 664 6k,6.6k - 4,650
ALE145AⅣ 0.75 25.7 908 25.7 908 145 71 380-440 4,700 4,700
0.86 23.9 844 23.8 840 3k,3.3k - 4,600
1.04 20.9 738 21.0 742 6k,6.6k - 4,650
ALE160AⅣ 0.75 28.3 999 28.1 992 160 73 380-440 4,700 4,700
0.86 25.6 904 25.6 904 3k,3.3k - 4,650
1.04 23.9 844 23.8 840 6k,6.6k - 4,900
ALE200AⅣ 0.75 35.4 1,250 35.4 1,250 200 JIS10k 80A FF 4,300×1,900×2,180
《 4,535×1,900×2,180 》
76 380-440 6,200 6,200
0.86 33.0 1,165 32.8 1,158 3k,3.3k - 6,050
1.04 29.8 1,052 29.6 1,045 6k,6.6k - 6,050
ALE250AⅣ 0.75 44.0 1,554 44.0 1,554 250 380-440 6,200 6,200
0.86 40.5 1,430 40.4 1,427 3k,3.3k - 6,050
1.04 37.3 1,317 37.3 1,317 6k,6.6k - 6,550
ALE275AⅣ 0.75 47.6 1,681 47.6 1,681 275 380-440 6,250 6,250
0.86 43.9 1,550 44.0 1,554 3k,3.3k - 6,450
1.04 40.4 1,427 40.4 1,427 6k,6.6k - 6,650

Water cooled model

Model Cooling water Quantity △T Water inlet
temperature
Water inlet / outlet connection Initial lubricant charge
L / min L
ALE132WVⅣ
ALE132WⅣ
238 10 32 JIS10k 50A FF 25
ALE145WⅣ 261
ALE160WVⅣ
ALE160WⅣ
288
ALE200WⅣ 355 JIS10k 65A FF 30
ALE250WVⅣ
ALE250WⅣ
443
ALE275WⅣ 487
ALE315WⅣ 492 JIS10k 80A FF 50
ALE355WⅣ 555
ALE400WⅣ 625

Air cooled model

Model Cooling fan motor output Initial lubricant charge
kW L
ALE132AVⅣ
ALE132AⅣ
6
( 3kW×2 )
35
ALE145AⅣ
ALE160AVⅣ
ALE160AⅣ
ALE200AⅣ 11
( 5.5kW×2)
51
ALE250AVⅣ
ALE250AⅣ
ALE275AⅣ

* Suction conditions Absolute suction pressure: 0.10MPa, Suction temperature: 30°C, Humidity: 75%RH
* Discharge air volumes is converted to suction conditions.
* Discharge pressures are measured after gas coolers.
* Air produced by compressors should not be used in respiratory equipment furnishing air for direct inhalation.
* Nominal working pressure![0.75MPa model: 0.70MPa, 0.86MPa model: 0.80MPa, 1.04MPa model: 0.90MPa]
* Since the cooling for the compressed air & the inside of the compressor unit depends on the surrounding air condition, the surrounding air must be properly ventilated to prevent the ambient temperature from rising above 45°C.(For air-cooled 1.04MPa model, the surrounding air temperature should not exceed 40°C)
* Please be sure to use the lubricating oil recommended by KOBELCO.
* Appearance and specifications are subject to change without notice.
* Consult us individually, regarding guaranteed performance values.
* For other voltage variants, please consult us.